Test Standards for the Electromagnetic Compatibility Directive

EMC-Non-Reflective Room Tests
- RF Electromagnetic Field Immunity by Radiation Posted by TS EN 61000-4-3 (80MHz-8GHz)
- (55011MHz-55013GHz) Propagation Corruption (TS EN 55022)
EMC-Immune Through Transmission Cage
- TS EN 61000-4-2 Immunity to Electrostatic Discharge
- TS EN 61000-4-4 Electrical Rapid Transient Regime, Explosion Immunity
- TS EN 61000-4-5 Immunity to sudden rise
- By TS EN 61000-4-6 RF Fields End. Against Transmitted Degradation.
- TS EN 61000-4-8 Network Frequency Magnetic Field Immunity
- TS EN 61000-4-9 Immunity to Pulse Shaped Magnetic Fields
- TS EN 61000-4-10 Damped and Oscillating Magnetic Field Test
- TS EN 61000-4-11 Voltage pits, short interruptions and voltage changes
EMC-Radio TV Immunity Cage Tests
- TS EN 55020 Antenna Input Immunity Test (S1)
- TS EN 55020 RFI Voltage Immunity Test (S2a)
- TS EN 55020 RFI Current Immunity Test (S2b)
- TS EN 55020 Immunity to Spreading Areas (S3)
- TS EN 55020 Shielding Effectiveness Test (S4)
EMC-Lighting Equipment Tests
- TS EN 55015 Distortion measurements transmitted and transmitted from lighting devices:
- Connector distortion voltage (9kHz-30MHz)
- Magnetic field propagation deterioration (9kHz-30MHz)
EMC-Conducted Emission Tests
- Connection distortion voltage (55011kHz-55013MHz) TS EN 55014, TS 1, TS EN 55022-150
- TS EN 55014-1 Connection distortion force (30-300MHz)
EMC-Click (Test) Tests
- TS EN 55014-1 Click (Transmitted Transmitted)
EMC-Harmonic & Flicker Tests
- TS EN 61000-3-2 harmonic current disturbances
- TS EN 61000-3-3 Voltage Fluctuations and Flicker Test
- TS EN 61000-4-13 Harmonic Immunity Assays
EMC-Open Area Tests
- TS EN 55011, TS EN 55013
General Test Standards
- TS EN 61000-4-2 Electrostatic Discharge Immunization Test
- TS EN 61000-4-3 Radiated Electromagnetic Field Immunity Test (20MHz - 3GHz, 30V / m)
- TS EN 61000-4-4 Electrical Rapid Transient Regime / Explosion Immunity Assay
- TS EN 61000-4-5 Immunity Test against Sudden Elevations
- Immune Assay Against Transmitted Degradation Induced by RF Areas in TS EN 61000-4-6
- TS EN 61000-4-8 Network Frequency Magnetic Field Immunity Test
- Pulse Shaped Magnetic Field Immunity Test TS EN 61000-4-9
- TS EN 61000-4-11 Immunity Test for Voltage Pits, Short Interruptions and Voltage Changes
- Common Mode Degradation in 61000-4-16 0Hz - 150 kHz Frequency Range
- TS EN 61000-3-2 Current Harmonics
- TS EN 61000-3-3 Voltage Fluctuations and Snapping Limit Values
- TS EN 55011, TS EN 55025 Connection End Distortion Voltage
- Home Appliances, Electrical Appliance and related apparatus: TS 4008 EN 55014-1
- TS EN 61000-6-1, TS EN 61000-6-3
- TS EN 61000-6-2, TS EN 61000-6-4 Industrial Media Devices
- TS EN 60601-1-2 Electrical Medical Devices
- TS EN 61326-1 Electrical Devices for Measurement, Control and Laboratory Use
- TS EN 61204-3 Low Voltage Power Supplies (DA Output)
- Electromagnetic Compatibility and Electromagnetic Compatibility for Radio Equipment and Services Immune and Propagation Tests
- TS EN 12015, TS EN 12016 Lifts, Control Equipments Used in Escalators
- TS EN 60974-10 Arc Welding Devices
- TS EN 62040-1, TS EN 62040-2 Uninterruptible Power Systems (KGS)
- TS EN 62310-2 Static Transfer Systems - Part 2: Electromagnetic Compatibility Requirements
- TS EN 50293 Road Traffic Sign Systems
- TS 7425 EN 60730-1 Automatic Control Layouts
- TS EN 50130-4 Electromagnetic Compatibility - Immunity Assays for Fire, Burglar and General Purpose Alarm Systems
- TS EN 50270 Devices that detect flammable and toxic gases
- TS EN 61547 General Lighting Devices
- IEC 60533 Electrical and Electronic Installations in Ships
- TS EN 50121-3-2 Railway Applications-Electromagnetic Compatibility Section 3-2
- TS EN 60255-26 Electromagnetic Compatibility Guidelines for Measuring Relays and Protection Devices
- OIML R 117-1 Dynamic Liquid Measurement Systems
- ISO 7637-2, ISO 7637-3 Electrical, Electronic Devices Used in Automotive
Immunity Tests in EMC Laboratories
- TS EN 61000-4-2 Immunity to Electrostatic Discharge (Airborne: 2-16.6kV, Contact: 1-8kV)
- RF Electromagnetic Field Immunization via Radiation (61000MHz-4GHz, 3-80-1V / m)
- TS EN 61000-4-4 Electrical Rapid Transient Regime / Explosion Immunity
- Immune to Imminent Elevations (61000-4kV in the Open Circuit Voltage Rise: 5 / 0.5ms, Short Circuit Current Rise: 4 / 1.2ms)
- Immune to Conducted Distortion Induced by RF Areas (61000kHz-4MHz range; 6 V levels)
- EN 61000-4-8: Mains Frequency Magnetic Field Immunity (3,30 A / m)
- TS EN 61000-4-11 Immunity to Voltage Pits, Short Interruptions and Voltage Changes (0.UT-% 100-0.05ms at 9999.UT)
- TS EN 61000-4-12: Oscillating Waves Immunity
- TS EN 61000-4-18 Damped Oscillating Waves Immunity
Publication Tests in EMC Laboratories
- TS EN 61000-6-3, TS EN 61000-6-4 Connector Distortion Voltage (150kHz - 30MHz)
- TS EN 61000-6-3, TS EN 61000-6-4 Dissipation Distortion (30MHz-1GHz)
- TS EN 61000-3-2 Harmonics (2-40. Harmonic)
- TS EN 61000-3-3 Voltage Fluctuations and Flicker (Short and Long Term)